The portable CRS-T4 system can be used for computer registration of any kind of pressure test system. By connecting the pressure sensors to the test line an accurate digital reading is provided via the Ventil test software.
The Windows operated ‘CRS’, exists of rugged laptop computer, a set of accurate - calibrated pressure transducers, A/D conversion unit and fully in-house developed test software.
Besides digital reading of the test data (pressure, time and leakage), the Ventil CRS system includes a variety of unique functions to help the operator with achieving accurate and reliable test results, for example; automatic verification of the found set pressure and leakage against the applicable ASME/API standards or a user defined tolerance.

Range: 0-200 bar (2,900 psi)
Software selection for: Pressure Relief Valves, Shut off valves or Control valves
Available connections: 1 USB, 1 sensor, 1 battery charge, 1 bubble counter
Power supply: 230 V 50-60 Hz (other on request)
Digital presure measurement:
- 0-60 bar (870 psi) 0,3% F.S. I 0-1,000 psi 0,3% F.S.
- 0-200 bar (2,900 psi) 0,3% F.S. I 0-3,000 psi 0,3% F.S.



Thank you for your